Details
Victron Quattro 12V 230V 3000VA Inverter Charger 50 Hz
The Victron Quattro is a pure sinewave inverter with a built in chargers. The Quattro can be connected to two different AC sources such as the grid/shore-side power and a generator. The Victron Quattro will automatically connect to the active source. If both AC sources are down the Victron Quattro will switch to the battery bank.
Quattro | 12/5000/220 |
PowerControl / PowerAssist | Yes |
Integrated Transfer switch | Yes |
AC inputs (2x) | Input voltage range: 187-265 VAC Input frequency: 45 – 65Hz Power factor: |
Maximum feed through current (A) | 2x100 |
INVERTER | |
Input voltage range (V DC) | 9.5 – 17V |
Output (1) | Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% |
Cont. output power at 25 °C (VA) (3) | 5000 |
Cont. output power at 25 °C (W) | 4500 |
Cont. output power at 40 °C (W) | 4000 |
Peak power (W) | 10000 |
Maximum efficiency (%) | 94 |
Zero-load power (W) | 25 |
Zero load power in AES mode (W) | 120 |
Zero load power in Search mode (W) | 5 |
CHARGER | |
Charge voltage 'absorption' (V DC) | 14.4 |
Charge voltage 'float' (V DC) | 13.8 |
Storage mode (V DC) | 13.2 |
Charge current house battery (A) (4) | 220 |
Charge current starter battery (A) | 4 (12V and 24V models only) |
Battery temperature sensor | Yes |
GENERAL | |
Auxiliary output (A) (5) | 50 |
Programmable relay (6) | 3x |
Protection (2) | a-g |
VE.Bus communication port | For parallel and three phase operation, remote monitoring and system integration |
General purpose com. port (7) | 2x |
Remote on-off | Yes |
Common Characteristics | Operating temp.: -40 to +50 ?C Humidity (non condensing): max. 95 |
ENCLOSURE | |
Common Characteristics | Material & Colour: aluminium (blue RAL 5012) Protection category: IP 2 |
Battery-connection | Four M8 bolts (2 plus and 2 minus connections) |
230 V AC-connection | Bolts M6 |
Weight (kg) | 34 |
Dimensions (hxwxd in mm) | 470 x 350 x 280 |
STANDARDS | |
Safety | EN 60335-1, EN 60335-2-2 |
Emission, Immunity | EN55014-1, EN 55014-2, EN 61000-3-3, EN 61000-6-3, EN 61000-6-2, EN 61000-6-1 |
1) Can be adjusted to 60 HZ; 120 V 60 Hz on request 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high |
3) Non linear load, crest factor 3:1 4) At 25 ?C ambient 5) Switches off when no external AC source available 6) Programmable relay that can a. o. be set for general alarm, DC undervoltage or genset start/stop function AC rating: 230V/4A DC rating: 4A up to 35VDC, 1A up to 60VDC 7) A. o. to communicate with a Lithium Ion battery BMS |